Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorGül, Enes Elvin
dc.contributor.authorBaudinaud, Pierre
dc.contributor.authorWaldmann, Victor
dc.contributor.authorSabbag, Avi
dc.contributor.authorJubeh, Yousef
dc.contributor.authorClementy, Nicholas
dc.contributor.authorOllitraut, Pierre
dc.contributor.authorConti, Sergio
dc.contributor.authorCarabelli, Adrian
dc.contributor.authorDoğan, Zeki
dc.date.accessioned2024-04-18T17:46:40Z
dc.date.available2024-04-18T17:46:40Z
dc.date.issued2024en_US
dc.identifier.citationGul, E. E., Baudinaud, P., Waldmann, V., Sabbag, A., Jubeh, Y., Clementy, N., Bisson, A., Ollitraut, P., Conti, S., Carabelli, A., & Dogan, Z. (2024). Leadless pacemaker implantation following tricuspid interventions: multicenter collaboration of feasibility and safety. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 10.1007/s10840-024-01796-w. Advance online publication. https://doi.org/10.1007/s10840-024-01796-wen_US
dc.identifier.issn1572-8595
dc.identifier.urihttps://hdl.handle.net/20.500.12900/370
dc.description.abstractBackgroundPermanent pacing is often required following valve intervention (either surgical or percutaneous); however, tricuspid interventions pose specific challenges to conventional pacing. Therefore, leadless pacemaker (LP) implantation may be the preferred strategy when permanent pacing is required after tricuspid valve intervention.PurposeTo report periprocedural outcomes and follow-up of patients undergoing implantation of a LP system following tricuspid valve interventions.MethodsPatients with previous tricuspid valve intervention at the time of attempted implantation of a LP (MicraTM, Medtronic, Minneapolis, MN, USA) were included.ResultsBetween 2019 and 2022, 40 patients underwent LP implantations following tricuspid interventions in 5 large tertiary centers. The mean age was 68.9 +/- 13.7 years, and 48% patients were male. The indication for pacing was as following: AVB in 27 (68%) patients, AF with slow ventricular response in 10 (25%) patients, and refractory rapid atrial fibrillation (AF) referred to AV junction ablation in 3 (7%) patients. Most of the patients received Micra VR (78%). The procedure was successful in all patients. The mean procedural time is 58 +/- 32 min, and the median fluoroscopy time is 7.5 min. Electrical parameters were within normal range (threshold: 1.35 +/- 1.2 V@0.24 ms, impedance: 772 +/- 245 Ohm, R-wave: 6.9 +/- 5.4 mV). No acute complications were observed. During a mean follow-up of 10 months, electrical parameters remained stable, and 4 deaths were occurred (not related to the procedure).ConclusionA LP is a safe and efficient option following tricuspid valve interventions.en_US
dc.language.isoengen_US
dc.publisherSPRINGERen_US
dc.relation.isversionof10.1007/s10840-024-01796-wen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectLeadless pacemakeren_US
dc.subjectTricuspid valve interventionen_US
dc.subjectAtrioventricular blocken_US
dc.titleLeadless pacemaker implantation following tricuspid interventions: multicenter collaboration of feasibility and safetyen_US
dc.typearticleen_US
dc.departmentİstanbul Atlas Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorGül, Enes Elvin
dc.contributor.institutionauthorDoğan, Zeki
dc.relation.journalJOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster