Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorYenigün, Serdar
dc.contributor.authorErcal, Pınar
dc.contributor.authorÖzden Yenigün, Elif
dc.contributor.authorKatipoğlu, Ahmet Bülent
dc.date.accessioned2022-12-14T07:02:39Z
dc.date.available2022-12-14T07:02:39Z
dc.date.issued2021en_US
dc.identifier.citationYenigun, S., Ercal, P., Ozden-Yenigun, E., & Katiboglu, A. (2021). Influence of Abutment Design on Stress Distribution in Narrow Implants with Marginal Bone Loss: A Finite Element Analysis. The International Journal of Oral & Maxillofacial Implants, 36(4), pp. 640–649. https://doi.org/10.11607/jomi.8554 ‌en_US
dc.identifier.issn0882-2786
dc.identifier.issn1942-4434
dc.identifier.uriWOS: 000725721800006
dc.identifier.uriPubMed ID: 34411203
dc.identifier.urihttps://hdl.handle.net/20.500.12900/123
dc.description.abstractPurpose: The aim of this study was to determine the effect of solid (one-piece) and two-piece abutments on the stress profile of narrow implants with marginal bone loss. Materials and Methods: Solid and two-piece abutments were connected to a conical internal octagon-connection implant (3.3 mm in diameter, 10 mm in length) and restored with a single crown. Three-dimensional finite element analysis was used to simulate the stress distribution in implant models with different levels of marginal bone resorption (0, 1, 2, and 3 mm). The effect of the design variables under increased bone resorption scenarios, including abutment screw length and diameter, was assessed. Static loading was applied to determine the mechanical response of the implant and cortical and trabecular bone. Results: Marginal bone resorption levels dominated the mechanical response under static loading conditions. A marginal bone loss of 3 mm significantly increased stress values in the implant vicinity and abutment screw. Both abutment designs displayed similar stress distribution in the surrounding bone, but lower stress values were observed in the implant body with two-piece abutments. The abutment screw length was more effective in the resultant stress, as the longer screws reduced the stress in the implants. Conclusion: Marginal bone resorption magnitude is the crucial parameter in biomechanics to determine the mechanical behavior. As bone loss increases, resultant stress around implants under mastication forces may lead to implant failure, regardless of abutment type.en_US
dc.language.isoengen_US
dc.publisherQuentissence Publishingen_US
dc.relation.isversionof10.11607/jomi.8554en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDental implantsen_US
dc.subjectFinite element analysisen_US
dc.subjectMarginal bone lossen_US
dc.titleInfluence of abutment design on stress distribution in narrow implants with marginal bone loss: a finite element analysisen_US
dc.typearticleen_US
dc.departmentİstanbul Atlas Üniversitesi, Diş Hekimliği Fakültesien_US
dc.authoridKatipoğlu, Ahmet Bülent / 0000-0001-7505-9953en_US
dc.contributor.institutionauthorKatipoğlu, Ahmet Bülent
dc.identifier.volume36en_US
dc.identifier.issue4en_US
dc.identifier.startpage640en_US
dc.identifier.endpage649en_US
dc.relation.journalInternatıonal journal of oral & maxıllofacıal ımplantsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster