Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorMercan, Çiğdem
dc.contributor.authorBulutsuz, Aslı Günay
dc.contributor.authorKatipoğlu, Ahmet Bülent
dc.date.accessioned2023-12-28T08:19:28Z
dc.date.available2023-12-28T08:19:28Z
dc.date.issued2023en_US
dc.identifier.citationMercan, C., Günay Bulutsuz, A., & Katiboglu, A. B., (2023). Systemic observation and measurement of microgap formation in dental implant–abutment connection interface under fatigue. Materials Testing , vol.65, no.11, 1-15.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12900/275
dc.description.abstractToday, a variety of implant designs with different attachment types are widely used in dental implant systems to eliminate connection problems. However, there are still design issues that can significantly affect the long-term success of dental implants. One of these problems is the formation of a microgap in the abutment-implant interface, which can lead to abutment screw loosening, screw fracture, and abutment fracture under masticatory loading. In this in vitro study, the effects of gingival height, dental implant diameter, and abutment type (solid, digital, and ball) on microgap formation were observed after repetitive fatigue tests using an experimental design. After the tests, the optimal design factors were determined to minimize microgap formation. According to the results of the experimental design, the abutment type was found to be the most influential parameter on microgap formation. An implant diameter of 4.1 mm, the smallest gingival height of 0.5 mm, and a digital attachment combination were identified as the optimal design parameters based on the statistical approach (R-2 = 85.3 %).en_US
dc.language.isoengen_US
dc.publisherWalter de Gruyteren_US
dc.relation.isversionof10.1515/mt-2023-0071en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMikro boşluken_US
dc.subjectMicrogapen_US
dc.subjectYorgunluk testien_US
dc.subjectFatigue testen_US
dc.subjectDeneysel tasarımen_US
dc.subjectExperimental designen_US
dc.subjectDiş implantı-dayanak arayüzüen_US
dc.subjectDental implant-abutment interfaceen_US
dc.subjectÖlçümen_US
dc.subjectMeasurementen_US
dc.titleSystemic observation and measurement of microgap formation in dental implant-abutment connection interface under fatigueen_US
dc.typearticleen_US
dc.departmentİstanbul Atlas Üniversitesi, Diş Hekimliği Fakültesien_US
dc.authoridAhmet Bülent Katiboğlu / 0000-0001-7505-9953en_US
dc.contributor.institutionauthorKatipoğlu, Ahmet Bülent
dc.identifier.volume65en_US
dc.identifier.issue11en_US
dc.identifier.startpage1679en_US
dc.identifier.endpage1685en_US
dc.relation.journalMaterials Testingen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster